Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
JACC Clin Electrophysiol ; 9(9): 1914-1929, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37480871

RESUMEN

BACKGROUND: The anatomical substrate for left posterior fascicular ventricular tachycardia (LPF-VT) is still unclear. OBJECTIVES: The purpose of this study is to describe the endocavitary substrate of the re-entrant loop of LPF-VT. METHODS: A total of 26 consecutive patients with LPF-VT underwent an electrophysiology study and radiofrequency ablation. RESULTS: Intracardiac echocardiography imaging observed a 100% prevalence of false tendons (FTs) at the left posterior septal region in all patients, and 3 different types of FTs could be classified according to their location. In 22 patients, a P1 potential could be recorded via the multielectrode catheter from a FT. In 4 patients without a recorded P1 during LPF-VT, the earliest P2 potentials were recorded from a FT in 3 patients, and from a muscular connection between 2 posteromedial papillary muscles in 1 patient. Catheter ablation focused on the FTs with P1 or earliest P2 (in patients without P1) was successful in all 26 patients. After 19 ± 8.5 months of follow-up, no patients had recurrence of LPF-VT. CONCLUSIONS: FTs provide an electroanatomical substrate for LPF-VT and a "culprit FT" may be identified as the critical structure bridging the macro-re-entrant loop. Targeting the "culprit FT" is a novel anatomical ablation strategy that results in long-term arrhythmia-free survival.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Ventrículos Cardíacos , Electrocardiografía/métodos , Bloqueo de Rama , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Técnicas Electrofisiológicas Cardíacas , Ablación por Catéter/métodos
3.
Pacing Clin Electrophysiol ; 44(2): 274-283, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32990323

RESUMEN

BACKGROUND: Post-ablation atrial tachycardias (ATs) are characterized by low-voltage signals that challenge current mapping methods. In this study, we analyzed common mistakes during activation mapping and delineated a mapping strategy for correct interpretation of tachycardia mechanisms in patients with challenging underlying substrate. METHODS AND RESULTS: Thirty-one patients referred for AT ablation were selected for the study. Three types of incorrect activation patterns were identified, which were referred to as unrecognized block line (pseudo-macroreentry and pseudo-fig-8 reentry), incorrect activation timing window of interest (WOI) (chaotic activation), and mis-annotation of complex signals (multiple sites of "early meets late"). Pseudo-macroreentry and chaotic activation occur in focal or localized reentry AT with the error related to the WOI selection (four cases), incorrect annotation of local activation time (six cases), or a previous line of atrial block in (seven cases). Pseudo-fig-8 reentry (five cases) and multiple sites of "early meets late" (nine cases) occur in macroreentrant AT with blocked areas and low-voltage atrial substrate. All ATs were successfully eliminated at the origin site. CONCLUSIONS: We delineated a series of ATs in the setting of a disordered pattern of activation mapping encountered in patients after previous extensive ablation or atriotomy. The algorithm proposed rapidly corrects the activation map and identifies the mechanism of the AT.


Asunto(s)
Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/cirugía , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
4.
J Cardiovasc Electrophysiol ; 31(4): 960-963, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32077548

RESUMEN

We present a case of wide-complex tachycardia in which the clinical electrophysiological diagnosis was considered to be bundle branch re-entry ventricular tachycardia. A series of ventricular entrainment attempts were performed from the left and right ventricular septum to confirm the diagnosis. Entrainment pacing with a general current output (10 mA) was performed from the right ventricular septum with manifest fusion and a post-pacing interval similar to tachycardia cycle length. Thereafter, another entrainment attempt with a greater current output (20 mA) was performed from the same site. Paradoxically, concealed fusion was demonstrated by selective RB capture only, though there was no clear "RB" potential seen. In this case, we attempt to explain and illustrate the mechanism of paradoxical near-field inability to capture with increasing current strength.


Asunto(s)
Potenciales de Acción , Fascículo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Taquicardia Ventricular/diagnóstico , Adulto , Femenino , Humanos , Valor Predictivo de las Pruebas , Taquicardia Ventricular/fisiopatología , Factores de Tiempo
5.
BMC Cardiovasc Disord ; 20(1): 48, 2020 02 03.
Artículo en Inglés | MEDLINE | ID: mdl-32013865

RESUMEN

BACKGROUND: Three-dimensional electroanatomic mapping systems have demonstrated a significant reduction in radiation exposure during radiofrequency catheter ablation procedures. We aimed to investigate the safety, feasibility and efficacy of a completely zero-fluoroscopy approach for catheter ablation of supraventricular tachycardia using the Ensite NavX navigation system compared with a conventional fluoroscopy approach. METHODS: A multicenter prospective non-randomized registry study was performed in seven centers from January 2013 to February 2018. Consecutive patients referred for catheter ablation of supraventricular tachycardia were assigned either to a completely zero-fluoroscopic approach (ZF) or conventional fluoroscopy approach (CF) according to the operator's preference. Patients with atrial tachycardia were excluded. RESULTS: Totally, 1020 patients were enrolled in ZF group; 2040 patients ablated by CF approach were selected for controls. There was no significant difference between the zero-fluoroscopy group and conventional fluoroscopy group as to procedure time (60.3 ± 20.3 vs. 59.7 ± 22.6 min, P = 0.90), immediate success rate of procedure (98.8% vs. 99.2%, P = 0.22), arrhythmia recurrence (0.4% vs. 0.5%, P = 0.85), total success rate of procedure (98.4% vs. 98.8%, P = 0.39) or complications (1.1% vs. 1.5%, P = 0.41). Compared with the conventional fluoroscopy approach, the zero-fluoroscopy approach provided similar outcomes without compromising the safety or efficacy of the procedure. CONCLUSION: The completely zero-fluoroscopy approach demonstrated safety and efficacy comparable to a conventional fluoroscopy approach for catheter ablation of supraventricular tachycardia, and mitigated radiation exposure to both patients and operators. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT03042078; first registered February 3, 2017; retrospectively registered.


Asunto(s)
Ablación por Catéter/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Exposición a la Radiación/prevención & control , Radiografía Intervencional , Cirugía Asistida por Computador/instrumentación , Taquicardia Supraventricular/cirugía , Potenciales de Acción , Adulto , Ablación por Catéter/efectos adversos , China , Técnicas Electrofisiológicas Cardíacas/efectos adversos , Femenino , Fluoroscopía , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Estudios Prospectivos , Exposición a la Radiación/efectos adversos , Radiografía Intervencional/efectos adversos , Recurrencia , Sistema de Registros , Factores de Riesgo , Cirugía Asistida por Computador/efectos adversos , Taquicardia Supraventricular/diagnóstico por imagen , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
6.
JACC Clin Electrophysiol ; 4(11): 1460-1470, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30466853

RESUMEN

OBJECTIVES: This study aimed to evaluate the electrophysiological mechanisms of post-surgical atrial tachycardias (ATs) during mapping with an automated high-resolution mapping system (Rhythmia, Boston Scientific, Marlborough, Massachusetts). BACKGROUND: Mapping and ablation of post-operative ATs following previous open-heart surgery is often challenging because the potential mechanisms remain incompletely understood. METHODS: Fifty-one consecutive patients underwent mapping and ablation of post-surgical ATs. RESULTS: A total of 64 ATs were identified, and the mechanism was macro re-entry in 58 of 63 (92.1%) ATs, focal in 4 ATs, localized micro re-entry in 1 AT, and undetermined in 1 AT. Of 11 patients who underwent surgical repair of congenital heart disease, 6 (54.5%) had peri-tricuspid re-entrant AT, 5 had either right atrial (RA) free-wall incisional ATs or figure-8 re-entrant ATs, with an isthmus between the tricuspid annulus and the RA free-wall incision or between the incisions, and none had left atrial (LA) or focal ATs. In 32 patients with valve replacement and 8 who underwent valvuloplasty, peri-tricuspid ATs were observed in 14 (43.4%) and 6 (75%) patients, RA free wall or septal incisions-related ATs were seen in 7 and 2 patients, and LA macro re-entrant ATs were observed in 12 patients and 1 patient, respectively. A macro pseudo re-entry pattern was identified in 8 of 51 patients (15.7%). All these activations could be easily excluded by manually moving the window of interest, except in 2 cases with a figure-8 re-entrant configuration. CONCLUSIONS: RA macro re-entrant ATs predominate, irrespective of the types of initial surgical procedures, but LA ATs occur more frequently in patients with valve replacement. Pseudo re-entry atrial activation is common and easily recognized by adjusting the mapping window.


Asunto(s)
Técnicas Electrofisiológicas Cardíacas/métodos , Complicaciones Posoperatorias , Taquicardia , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/fisiopatología , Estudios Prospectivos , Taquicardia/diagnóstico , Taquicardia/fisiopatología
10.
Artículo en Inglés | MEDLINE | ID: mdl-29138142

RESUMEN

BACKGROUND: We report the 12-lead ECG morphology of left posterior fascicular ventricular tachycardia (LPF-VT) and the relationship between His-ventricular (HV) interval and site of origin in LPF-VT. METHODS AND RESULTS: We studied 41 patients who underwent successful catheter ablation of LPF-VT with HV interval >0 ms (n=8; proximal-LPF group), HV interval 0 to -15 ms (n=15; middle-LPF group), and HV interval <-15 ms (n=18; distal-LPF group). The earliest mapped presystolic potential (PP)-QRS interval was 34.1±4.2, 24.5±3.2, and 19.4±2.8 ms in proximal-, middle-, and distal-LPF groups. The earliest PP ratio (PP-QRS interval during VT/HV interval during sinus rhythm) was 0.59±0.05, 0.45±0.07, and 0.31±0.05 in the proximal-, middle-, and distal-LPF groups. There were statistically significant differences between the 3 groups in earliest PP ratio, and there was close correlation between the HV interval during LPF-VT and earliest PP ratio. The QRS duration in the proximal-LPF group (114±6 ms) was significantly narrower compared with the middle-LPF group (128±5 ms) and distal-LPF group (140±6 ms). In leads I and V6, the ratio of R/S tended to be greater in the proximal-LPF group compared with the other 2 groups. QRS duration, the ratio of R/S in leads V6, and lead I could predict a proximal or distal origin site of LPF-VT with high sensitivity and specificity. CONCLUSION: The HV interval and 12-lead ECG morphology of LPF-VT may help predict the successful site of origin and prove useful in guiding an effective ablation strategy.


Asunto(s)
Ablación por Catéter , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/cirugía , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Potenciales de Acción , Adolescente , Adulto , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
11.
Tex Heart Inst J ; 44(2): 107-114, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28461795

RESUMEN

The efficacy of pulmonary vein antral isolation for patients with prolonged sinus pauses (PSP) on termination of atrial fibrillation has been reported. We studied the right atrial (RA) electrophysiologic and electroanatomic characteristics in such patients. Forty patients underwent electroanatomic mapping of the RA: 13 had PSP (group A), 13 had no PSP (group B), and 14 had paroxysmal supraventricular tachycardia (control group C). Group A had longer P-wave durations in lead II than did groups B and C (115.5 ± 15.4 vs 99.5 ± 10.9 vs 96.5 ± 10.4 ms; P=0.001), and RA activation times (106.8 ± 13.8 vs 99 ± 8.7 vs 94.5 ± 9.1 s; P=0.02). Group A's PP intervals were longer during adenosine triphosphate testing before ablation (4.6 ± 2.3 vs 1.7 ± 0.6 vs 1.5 ± 1 s; P <0.001) and after ablation (4.7 ± 2.5 vs 2.2 ± 1.4 vs 1.6 ± 0.8 s; P <0.001), and group A had more complex electrograms (11.4% ± 5.4% vs 9.3% ± 1.6% vs 5.8% ± 1.6%; P <0.001). Compared with group C, group A had significantly longer corrected sinus node recovery times at a 400-ms pacing cycle length after ablation, larger RA volumes (100.1 ± 23.1 vs 83 ± 22.1 mL; P=0.04), and lower conduction velocities in the high posterior (0.87 ± 0.13 vs 1.02 ± 0.21 mm/ms; P=0.02) and high lateral RA (0.89 ± 0.2 vs 1.1 ± 0.35 mm/ms; P=0.04). We found that patients with PSP upon termination of atrial fibrillation have RA electrophysiologic and electroanatomic abnormalities that warrant post-ablation monitoring.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Función del Atrio Derecho , Técnicas Electrofisiológicas Cardíacas , Venas Pulmonares/cirugía , Nodo Sinoatrial/fisiopatología , Potenciales de Acción , Adenosina Trifosfato/administración & dosificación , Anciano , Fibrilación Atrial/fisiopatología , Estimulación Cardíaca Artificial , Ablación por Catéter , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Recuperación de la Función , Factores de Tiempo , Resultado del Tratamiento
12.
Heart Rhythm ; 13(7): 1460-7, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26961304

RESUMEN

BACKGROUND: In patients with idiopathic left ventricular tachycardia (ILVT), the arrhythmogenic substrate is poorly understood. OBJECTIVE: The purpose of this study was to elucidate the ILVT characteristics and outcome of radiofrequency catheter ablation in patients with ILVT. METHODS: Twenty-four patients with ILVT and 15 patients with left accessory pathways (control) underwent high-density mapping of the left His-Purkinje system during sinus rhythm (SR) using 3-dimensional electroanatomic mapping. RESULTS: Fragmented antegrade Purkinje potential (FAP) was represented at the left ventricular septum slightly inferoposterior to the left posterior fascicle (LPF) in 23 patients with ILVT. In control subjects, no FAPs could be recorded at the same region, FAPs were identified at the proximal portion of the LPF (4 patients) and at the distal LPF (1 patient). The finding of any FAPs in ILVT patients was significantly higher than that in control patients (23/24 vs 5/15, P < .01). Radiofrequency ablation at the area of FAP resulted in successful ablation in 23 patients with ILVT. No ILVT recurred during follow-up of 16.3 ± 7.2 months. CONCLUSION: In patients with ILVT, FAP located at the left ventricular septum slightly inferoposterior to the LPF is a novel finding using 3-dimensional electroanatomic mapping. The FAP may represent an arrhythmogenic substrate in ILVT and may be used for guiding successful ablation.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Ventrículos Cardíacos , Taquicardia Ventricular , Adolescente , Adulto , Ablación por Catéter/métodos , Ecocardiografía Tridimensional/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Femenino , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Evaluación de Procesos y Resultados en Atención de Salud , Ramos Subendocárdicos , Reproducibilidad de los Resultados , Cirugía Asistida por Computador/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología
19.
Circ Arrhythm Electrophysiol ; 4(6): 902-8, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21985795

RESUMEN

BACKGROUND: Catheter ablation of atrial tachycardia (AT) arising near the coronary cusps has been reported in limited numbers of patients. We investigated the electrophysiological characteristics of these ATs in 22 consecutive patients. METHODS AND RESULTS: This study included 22 patients (mean age ± SD, 53 ± 11 years; 86% female) with ATs arising near the aortic coronary cusps who underwent successful ablation. Activation mapping was performed during tachycardia to identify the earliest activation site. All patients achieved successful ablation through either a retrograde aortic (n=19) or a transseptal (n=3) approach. The successful ablation sites were located in the noncoronary cusp (NCC) (n=16), including 3 near the junction between the NCC and right coronary cusp. The remaining 6 cases were ablated from the left coronary cusp (LCC) (n=3) or the left atrium posterior to the LCC (n=3). For most tachycardias, there were distinctive P-wave morphological features recorded for each cusp location. Furthermore, analysis of the electrogram morphological features recorded during tachycardia at successful ablation sites revealed an atrial/ventricular (A/V) ratio >1 in 14 of 16 NCC ATs; the remaining 2, from the NCC near the junction with the right coronary cusp, showed an A/V ratio ≤ 1. At ablation sites in the LCC, the A/V ratio was <1 (4 of 6 patients) or 1 (remaining 2 patients). During a follow-up duration of 30 ± 13 months, all patients were free of arrhythmias without antiarrhythmic drugs. CONCLUSIONS: ATs surrounding the aortic coronary cusps can be safely and effectively ablated, with good long-term outcomes. In addition to the P-wave morphological features, the A/V ratio of the local electrogram recording during tachycardia facilitated the localization of successful sites.


Asunto(s)
Válvula Aórtica/fisiopatología , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/fisiopatología , Taquicardia Supraventricular/diagnóstico , Adulto , Válvula Aórtica/cirugía , Estimulación Cardíaca Artificial , Ablación por Catéter , China , Femenino , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/cirugía , Humanos , Los Angeles , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Seno Aórtico/fisiopatología , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/cirugía , Factores de Tiempo , Resultado del Tratamiento
20.
Heart ; 97(13): 1034-40, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21478384

RESUMEN

CONTEXT: Previous randomised controlled trials (RCT) regarding n-3 PUFA supplementation for atrial fibrillation (AF) prevention have yielded conflicting results. OBJECTIVE: A systematic review and meta-analysis of RCT was conducted to examine the role of n-3 PUFA in AF prevention. DATA SOURCES: MEDLINE, Web of Science and Cochrane clinical trials database were searched until November 2010. STUDY SELECTION: Of 127 initially identified studies, 10 RCT with 1955 patients were finally analysed. DATA EXTRACTION: Two blinded reviewers extracted data independently to a predefined form. Disagreements were resolved through discussion and consensus. RESULTS: n-3 PUFA had no significant effect on the prevention of AF (OR 0.81, 95% CI 0.57 to 1.15; p=0.24). There was significant heterogeneity among the studies (p=0.002, I(2)=65.0%). Subgroup analysis showed no significant beneficial effect of fish oils in any subset of population. CONCLUSIONS: No significant effects of n-3 PUFA supplementation on AF prevention were observed in this meta-analysis. A large-scale trial with higher doses and longer follow-up might be required to rule out the possibility of any treatment benefit.


Asunto(s)
Fibrilación Atrial/prevención & control , Suplementos Dietéticos , Ácidos Grasos Omega-3/uso terapéutico , Fibrilación Atrial/diagnóstico , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto , Proyectos de Investigación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA